CDU Fieldnotes

Evidence record

CDU comparison sources and method

The site shows reviewed statements from vendor pages. Source dates and limits are collected here.

Reviewed vendor pages

Shared limits and how to read the claims

Vendor pages establish what those vendors state. They do not establish measured performance. The selected evidence does not provide a matched independent test, a public numeric price, or evidence of stability across dates.

Claims are bound to exact candidate and source snapshot hashes in the project’s internal dependency record. If a source or reviewed fact changes, every dependent page is flagged for review before publication.

Feedback

Feedback analysis used 21 selected records (2 posts and 19 comments) after documented exclusions. 18 matched one or more candidate concerns; 0 had matching recorded vendor evidence and 0 was fully answered.

History

These captures establish first observations dated 2026-11-13 (plus Johnson Controls document revision dated 2026-09-30). No across-date validation exists in this draft.

LiquidStack and Rittal add two covered seller groups in the new source register below. Earlier six-seller counts refer to the original CSV snapshot.

Sources for the added decision fields

Read dates and saved passages are below. Download these fields (CSV).

LiquidStack · Capacity and ATD

LiquidStack CDU 2.X: up to 2.5 MW at 4°C ATD.

End-of-row or rack-adjacent use. A headline rating is not a site load guarantee; obtain the full operating curve.

liquidstack-cdu2x · Read 2026-11-14T03:51:58.464766+00:00 · Vendor documentation

Saved passage and hashes

L43; exact character span 1945:1979 in retained returned representation

Snapshot c37aacb443c9a8dbe78a696dd4b11f9eabcad9115d6f8c6d310f5bd14e9ff12e

Claim fa0b58ef0b7cda374e5b548b0ca964a6f8808b3be25e594b60a75aa18c778830

LiquidStack · Facility inlet

The CDU 2.X page supports facility water inlet temperatures up to 45°C.

The page does not establish that maximum flow, capacity and inlet temperature occur together.

liquidstack-cdu2x · Read 2026-11-14T03:51:58.464766+00:00 · Vendor documentation

Saved passage and hashes

L82; exact character span 4017:4064 in retained returned representation

Snapshot c37aacb443c9a8dbe78a696dd4b11f9eabcad9115d6f8c6d310f5bd14e9ff12e

Claim ecbd51cf343e7fa27686810f7d3155f13959c75d4bc54018c2f46c1d66946396

LiquidStack · Hydraulic duty point

The sheet lists 3.5 bar / 50 psi available head at 3,750 lpm / 990 gpm.

Use the stated pair, not an isolated maximum flow; have the supplier confirm coolant and pressure-drop conditions.

liquidstack-datasheet · Read 2026-11-14T03:51:58.448369+00:00 · Vendor documentation

Saved passage and hashes

L48; exact character span 2862:2916 in retained returned representation

Snapshot de3b983b7f7f5cbe09e50da9b9d31f63b3476c0d021412077327c35cdad09a00

Claim ca7e3fe63cf276573c452ad6d75424d3371525b8b5d9d3ea77915ef606693841

LiquidStack · Pump modes

Single-pump mode provides internal N+1; dual-pump mode uses unit-to-unit redundancy.

Ask which operating mode your quote uses and what capacity remains after a pump fails.

liquidstack-datasheet · Read 2026-11-14T03:51:58.448369+00:00 · Vendor documentation

Saved passage and hashes

L47; exact character span 2761:2852 in retained returned representation

Snapshot de3b983b7f7f5cbe09e50da9b9d31f63b3476c0d021412077327c35cdad09a00

Claim a1962b58920de39b1ba4e062b4e4d16fb6c8944f1c2a83687994169a612dfb58

LiquidStack · Power and controls

Control options include differential pressure, flow or pump speed; power options include dual A/B feeds with or without ATS.

These are configuration choices, not features proven to be included in every quoted unit.

liquidstack-datasheet · Read 2026-11-14T03:51:58.448369+00:00 · Vendor documentation

Saved passage and hashes

L57; exact character span 3388:3443 in retained returned representation

Snapshot de3b983b7f7f5cbe09e50da9b9d31f63b3476c0d021412077327c35cdad09a00

Claim e69496ae08a5ec84fd9085c938fe50c2298e1db85fb20ba03a0abe5e8638be1d

Rittal · Liquid-to-liquid models

Rittal's US page lists a 150 kW in-rack CDU and 1 MW in-row CDU.

The same page's 70 kW rear-door liquid-to-air system is a different architecture. ATD for the L2L capacities is not stated there.

rittal-inrow · Read 2026-11-14T03:51:58.452543+00:00 · Vendor documentation

Saved passage and hashes

L26; exact character span 2136:2155 in retained returned representation

Snapshot 1dbee8db9d82e9c93f1a28f45c9054dac06701a8bcc3eb8c20f6b8b23ed42644

Claim f7e54483a62442873baa3f8d72b887cb2a054a202f1ae26f863ce56f8b32db38

Rittal · Service access

Rittal says in-row sensors, controller and pumps can be replaced while the system runs.

A vendor design claim, not a tested uptime result or a site-specific maintenance procedure.

rittal-inrow · Read 2026-11-14T03:51:58.452543+00:00 · Vendor documentation

Saved passage and hashes

L42; exact character span 4028:4129 in retained returned representation

Snapshot 1dbee8db9d82e9c93f1a28f45c9054dac06701a8bcc3eb8c20f6b8b23ed42644

Claim 092314a4b56abfd39123abb8d7b4d5684dd479d32fcd838f9f60c8883ec68586